ASTM E162 DOWNLOAD

19 Jun ASTM E TESTING. FOR TPR2. ON. FLEXIBLE FIRESHELLIM. MASTIC AFES -M1. VTEC # TESTED: JUNE 19, Unlike the ASTM E84 test, which requires a foot-long sample and costly testing equipment, the ASTM E surface flammability test is a much more. ASTM E Standard Test Method for Surface Flammability ASTM E Fire Test to Building Material Standard ASTM E Standard Test Method for Surface.

Author: Mikataur Yojora
Country: Mozambique
Language: English (Spanish)
Genre: Business
Published (Last): 8 October 2010
Pages: 398
PDF File Size: 14.53 Mb
ePub File Size: 13.98 Mb
ISBN: 928-4-38485-984-1
Downloads: 84657
Price: Free* [*Free Regsitration Required]
Uploader: Tezahn

This test method provides a laboratory test procedure for measuring and comparing the surface flammability of materials when exposed to a prescribed level of radiant heat energy. Finally, these two factors are combined to find the radiant panel index Is as in the astm e162 equation: The test is conducted using small specimens that are representative, to the extent possible, of the material astm e162 assembly being evaluated.

ASTM E | FireTEC

In addition, we proudly hold the following accreditations: The test is conducted using small astm e162 that are representative, to the extent possible, of the material or assembly being evaluated. This test method may involve hazardous materials, operations, and equipment. Above the material are a series of thermocouples mounted in a chimney, or astm e162, which measures the produced heat against known fuel sources. Calibration is performed by measuring temperature rise from flames produced with a methane calibration burner over a range of fuel flow rates.

Second, the heat evolution factor Q represents the quantity of fuel contained in the material. Therefore, the results are astm e162 only for the fire test exposure conditions described in this procedure.

For quick, e62 and reliable astm e162 flame spread testing of coatings, building products, materials and textiles used in railroad, transportation, and military applications, VTEC Laboratories is your number one choice. The test method was originally published in Its unique feature is that the sample is exposed to a 12 by in radiant heat source and reflects more accurately what might be found in a real fire environment.

TOP Related  VAMPYRE MAGICK THE GRIMOIRE OF THE LIVING VAMPIRE DOWNLOAD

Designed to help manufacturers meet safety standards in the construction of buses, trains, recreational vehicles and astm e162, the ASTM E test is a convenient and trusted method to learn how flames can spread across a material astm e162 environments like those found in a real fire. Finally, these two factors are combined to astm e162 the radiant panel index Is as in the following equation:. That represents the fastest turnaround time in the flammability axtm industry.

It is the responsibility of the user of this asgm to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the astm e162 of regulatory e1662 prior to use.

ASTM E162 Flammability Test

Once determined, the radiant panel index is helpful in assessing the overall fire hazard of the given material. The test is conducted by placing the material at a degree angle to a radiant astm e162 source, which is a porous panel that steadily burns a mixture of natural gas and air at degrees Fahrenheit.

Link to Active This link will always route to the current Active version of the standard. It is not intended for use as a astm e162 of ratings for building code purposes.

There is no similar or equivalent ISO standard. Site Credits Sitemap Privacy Policy. A heat evolution factor, Q, is determined from the max temperature rise astj specimen testing 4. The values given in parentheses are mathematical conversions to SI units that are provided for information astm e162 and are not considered standard.

TOP Related  AUTOSABOTAJE MARTHA BALDWIN EPUB DOWNLOAD

The test has not enjoyed the widespread adoption of ASTM E84, perhaps due astj misconceptions concerning its ability to connect to E84 flammability performance measurements.

Nevertheless, when viewed within its own frame of reference, this test method provides astm e162 valid flammability assessment.

In this procedure, the specimens are subjected to one or astm e162 specific sets of laboratory fire test conditions. It is intended for use in measurements of the surface flammability of materials exposed to fire.

Radiant Panel Flame Spread Apparatus

Vertical radiant panel test exposure configuration. At VTEC Laboratories, a popular flammability test we regularly conduct on behalf of transportation and astm e162 interests is the American Society for Testing and Materials ASTM E for surface flammability of materials sstm a radiant heat energy source. Fs is combined with Q astm e162 an overall flammability parameter, the radiant panel index, Is.

Historical Version s – view previous versions of standard. Once all samples and paperwork are received, we can complete the test for flame spread and astm e162 your astm e162 in just two weeks. If different test conditions are substituted or the end-use conditions are changed, it is not always possible by or from astm e162 test to predict changes in xstm fire-test-response characteristics measured. Learn more about our services by contacting us online or calling us at ASTM E is currently applied to materials for rapid rail transit and light rail transit vehicles and military applications among others.

The values given in parentheses are mathematical conversions to SI units that are astm e162 for information only and are not considered standard. Flame front propagation plot for 4.